Kaco blueplanet 92.0 TL3 US Manual page 63

Grid support interactive inverter
Table of Contents

Advertisement

Manual
Country-
Level Display/
spec. Set-
settings
tings
10 min. mean value
3
1
2
4
4
Overvoltage averag-
ing / country-depen-
dent [% Unom] /
%
Overvoltage protection
2
1
3
4
4
Transient overvoltage
1
2
3
4
4
protection
114.8 – 139.0 [%
Unom] /
tion 4} Page 15] /
0.1 %
Password protection
Status
Communication
1
4
2
3
4
Ethernet
2
4
1
3
4
IP Settings
3
1
2
4
4
DHCP
1
2
3
4
4
Status
IP Address
1
2
3
4
4
Subnet Mask
1
2
3
4
4
Default gateway
4
1
2
3
4
DNS server settings via
1
2
3
4
4
DHCP
Status
Primary DNS &
1
2
3
4
4
Secondary DNS (op-
tional)
Web Settings
1
2
3
4
4
HTTP Port
HTTPS Port
Modbus
3
4
1
2
4
Activation
4
1
2
3
4
Status
Write access
1
2
3
4
4
Status
KACO blueplanet 92.0 TL3 US KACO blueplanet 110 TL3 US KACO blueplanet 125 TL3 US
Configuration and operation | 9
Action in this menu/meaning
F Set the voltage in % using the mean value formation.
0,1
NOTE: Shutdown carried out within a grid cycle.
1. Shutdown carried out within a grid cycle.
2. Activate optional password protection.
3. Confirm action field.
[See sec-
Input screens for configuring the interfaces.
NOTE: Possibility to parameterise the Ethernet interface.
NOTE: Parameterization of network access.
F Activate or deactivate the DHCP.
On: Once the DHCP server becomes available, the IP address, subnet
mask, gateway and DNS server are automatically applied and the afore-
mentioned menu items are filled in.
Off: Apply settings manually.
F Allocate a unique IPv4 address in the network.
F Assign a subnet mask.
F Enter IPv4 address of the gateway.
F Activate or deactivate the DNS server from the DHCP.
On: Once the DHCP server becomes available, the IP address is automat-
ically applied and the aforementioned menu items are filled in.
Off: Apply settings manually.
1. Enter IPv4 address of DNS server.
2. Confirm the action field.
NOTE: Opportunity to set up the http ports.
F Set up the port at which the webserver can be reached.
1. Set up the safe port at which the webserver can be reached.
2. Confirm the action field.
NOTE: Option to set the Modbus port.
F Allow Modbus TCP read access.
F Allow Modbus TCP write access.
Enabling the write access allows system critical settings to be changed
over Modbus TCP. Really enable write access?
F Confirm the action field.
Page 63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Blueplanet 110 tl3 usBlueplanet 125 tl3 us

Table of Contents