9 | Configuration and operation
Country-
Level Display/
spec. Set-
settings
tings
Analyze Log Data
2
4
1
3
4
User logs
1
2
3
4
4
cosPhi | fac (Hz) |
lac 1 (A) | lac2 (A) |
lac3 (A) | idc (A) | Qac
(var)
Blueplanet web
1
2
3
4
4
Web portal
1
2
3
4
4
Select for activation
Logging interval
1
2
3
4
4
900 – 86400 [s]
900 [s]
Transfer interval
1
2
3
4
4
900 – 86400 [s]
900 [s]
Parameter Manage-
1
2
3
4
4
ment
Factory setting
2
1
3
4
4
Config. export.
2
1
3
4
4
Import configuration
2
1
4
4
3
Password protection
2
4
4
1
3
Country selection |
Connection conditions
| Advanced islanding
detection | FRT | ... | ...
|
Firmware update
2
4
4
1
3
Instant Update
3
1
2
4
4
Installation Wizard
2
1
3
4
4
Service
2
1
3
4
4
Page 74
Action in this menu/meaning
NOTE: All measurement data can be transferred to a USB stick
by making individual and multiple selections.
1. Select a date in the calendar.
2. Select measurement data from the dropdown field.
3. Update the measurement data.
4. Move the selected measurement data to the storage device or
move the data selectively.
F NOTE: Option to transmit live measurements to the KACO
Portal
F Activate continuous transmission.
F Specify measuring interval.
1. Specify transfer interval.
2. Confirm the action field.
NOTE: Option to reset configured values and the import and
export of specific parameters.
1. Compare all parameters / country-specific parameters / network-
specific parameters with default setting.
2. If necessary, reset the parameters by clicking on the "Restore" but-
ton.
1. Exporting parameters for device-independent settings / Export all
settings.
2. Select the parameters for export into a file or the plant manager.
1. Select the parameter file using the "Browse" button.
2. Import the parameters by clicking on the "Upload" button.
1. Opportunity to set up password protection for individual parame-
ters.
2. Confirm the action field.
NOTE: Opportunity to update the device. Parameter data are
not overwritten when the firmware is updated.
1. Select and confirm the firmware update file with the "Browse..."
button
2. Load the firmware with the "Browse" button.
3. Note: During the entire update process, the AC and DC supply of the
inverter must be ensured. A loss of supply may damage the device.
Continue with update?
NOTE: The installation wizard is described in the chapter [See sec-
tion 8.4} Page 40].
When the installation process is complete, the text: Installation wizard
was completed appears
NOTE: Opportunity to specify the service interval.
KACO blueplanet 92.0 TL3 US KACO blueplanet 110 TL3 US KACO blueplanet 125 TL3 US
Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Blueplanet 110 tl3 usBlueplanet 125 tl3 us