Johnson Controls tyco Power Pro Series Reference Manual page 108

Alarm controller
Table of Contents

Advertisement

Section 5: Programming
2 – AC Trouble Light Flashes
ON: When AC power is lost, the Trouble light flashes in the base "Ready" and "Armed" mode within 30 seconds of power
loss. When AC restores, the Trouble light stops flashing within 30 seconds. If enabled, this option overrides the AC display
option.
OFF: When AC power is lost, the Trouble light illuminates but does not flash.
3 – Keypad Blanking
ON: If no keys are pressed within 30 seconds, all keypad lights except backlighting (if enabled) are shut off until the next
keypress, entry delay, audible alarm or keypad buzzer condition.
Keypad function keys still operate when the keypad is blank, unless the function key is programmed to require an access
code. Keypad Blanking While Armed overrides this feature. When a partition is armed and in alarm, entering a code to
remove blanking silences the alarm and disarms the system.
OFF: The keypad lights remain ON at all times.
4 – Keypad Blanking Requires Code
ON: A valid access code must be entered before a blanked keypad can be used. Information becomes inaccessible to level
1 users.
OFF: Pressing any key on a blanked keypad removes keypad blanking.
Note: Keypad Blanking Requires Code must be set to off for CP-01 listed installations.
CP-01
5 – Keypad Backlighting
ON: All keypads on the system have backlighting on at all times.
OFF: All keypads on the system have backlighting off.
6 – Power Save Mode
ON: If AC power fails, all keypad lights including backlighting are shut OFF. The keypad lights come back ON after a
keypress, entry delay, audible alarm or keypad buzzer condition (except door chime). Keypad lights return to the off state
after 30 seconds of inactivity.
OFF: If AC power fails, keypads do not go into power save mode.
7 – Bypass Display When Armed
ON: The Bypass message is displayed if zones are bypassed when the system is armed.
OFF: The Bypass message is displayed only while the system is disarmed to indicate that zones on the system are
bypassed. When the system is armed, the Bypass light is off.
The Bypass message is displayed if Stay/Away zones are auto bypassed at the time of arming regardless of whether or not
this option is enabled. This option only enables and disables manual bypass message display.
8 – Keypad Tampers Enabled
ON: All keypads containing tamper switches generate tamper alarms and restores.
OFF: The tamper switches on all keypads do not generate tamper alarms.
Note: If this option is used, all keypads should be properly installed and secured (tamper restored) before enabling the
option.
NA
Note: Must be ON for UL/ULC commercial burglary listed installations.
[017] System Option 5
1 – Chime on Opening
ON: When a zone with the door chime attribute ON is opened, the system keypads and sirens (if enabled) beep.
OFF: When a zone with the door chime attribute ON is opened, the system keypads and sirens (if enabled) do not beep.
2 – Chime on Closing
ON: When a zone with the door chime attribute ON is closed, the system keypads and sirens (if enabled) beep.
OFF: When a zone with the door chime attribute ON is closed, the system keypads and sirens (if enabled) do not beep.
3 – RF Jam Trouble Beeps
ON: Trouble beeps sound when an RF Jam Trouble is detected
OFF: Trouble beeps do not sound when an RF Jam Trouble is detected