Note: This setting is required for EN50131-1 compliant installations using 1000 access codes.
[042] Verified Events
Burglary Verified Counter
This counter determines the number of burglary alarms that must occur within the Burglary verification window before a con-
firmed Burglary Verified alarm is logged and communicated. Zones with the burglary verification zone attribute enabled con-
tribute to the generation of a confirmed Burglary Verified alarm in conjunction with this counter and the burglary verification
timer.
Holdup Verification Counter
This counter determines the number of alarms that must occur within the Holdup verification window before a confirmed Hol-
dup alarm is logged and communicated. Zones with the holdup verification zone attribute enabled contribute to the gen-
eration of a confirmed Holdup alarm in conjunction with this counter and the holdup verification timer.
Burglary Verification Selection
Use this section to select one of the following burglary verification timer modes:
Mode
Description
001 Police Code
The burglary verification timer operates in minutes.
002 Cross Zoning
The burglary verification timer operates in seconds. The first alarm in the sequence does not log or communicate the
alarm or activate the bell.
003 Sequential
The burglary verification timer operates in minutes. The first alarm in the sequence causes an audible bell.
Detection
Partition Setup
[151]-[158] Partition Auto-Arm/Disarm
Enter section 151 to 158 for partition 1 to 8 auto-arm/disarm configuration.
[001] – Partition Auto-Arming Times
Use this section to program the time of day a partition is automatically armed. A different auto-arming time can be pro-
grammed for each day of the week from Sunday to Saturday. Time is in 24-hour format (HH:MM) and valid entries are from
00:00 to 23:59.
Conditions that cancel auto-arming if enabled:
Open zones (depending on the settings of the zone)
l
AC/DC troubles
l
System troubles
l
Any valid disarming procedure - proximity tag, access code, disarm key, etc.
l
[002] – Partition Auto-Disarm Times
Use this section to program the time of day a partition is disarmed. A different auto-disarming time can be programmed for
each day of the week from Sunday to Saturday. Time is in 24-hour format (HH:MM) and valid entries are from 00:00 to 23:59.
Note: If entry delay is active at auto-disarm time, the system does not disarm. A valid disarming procedure is required by the
user who initiated the entry delay.
[003] – Partition Auto-Disarming Holiday Schedules
Use this section to select a holiday schedule group.
See "[711]-[714] Holiday Schedules" on page 135for more information.
[004] – Partition Auto-Arming Pre-Alert Timer
Use this section to program the duration of the auto-arm pre-alert. The system arms when the pre-alert timer expires. Valid
entries are from 001 - 255 minutes.
If a valid access code is keyed in, this timer is postponed for the length of time programmed in Partition Auto-Arm Postpone
timer (see below). The pre-alert timer can be postponed multiple times. Keyswitches and proximity tags can be used to can-
cel auto-arming.