Johnson Controls tyco Power Pro Series Reference Manual page 129

Alarm controller
Table of Contents

Advertisement

UL
Note: Maximum 45 seconds for UL installations.
[015] – T-Link Wait for Ack
This option is used to program the length of time the communicator waits for an acknowledge after transmitting via IP/GS.
Valid entries are 001 to 255. Default is 60 seconds.
[016] –IP/Cellular Fault Check Timer
This section is used to program the number of poll commands sent without valid poll responses before the alarm system gen-
erates a trouble condition. The checks occur at 3-second intervals.
Valid entries are 003-255 for trouble annunciation and transmission.
The trouble restore is not delayed.
[380] Communicator Option 1
1 – Communications Enabled/Disabled
ON: (Default) The system communicator is enabled and all events with reporting codes are reported to the monitoring sta-
tion. Refer to the Telephone Number, Reporting Code and Call Direction programming sections.
OFF: The system communicator is disabled and no events are reported to the monitoring station.
Note: Disabling the communicator clears all FTC troubles.
2 – Restore On Bell Timeout
ON: Zone restore reporting codes are not transmitted until the zone has been restored and the bell timeout has expired. If the
zone is not restored when the bell cut-off time expires, the restore is transmitted when the zone physically restores or when
the system is disarmed.
Note: 24-hour zones will not restore until the zone is physically restored
OFF: Zone restore reporting codes are transmitted when the zone is physically restored. If zones are still active when the sys-
tem is disarmed, the restore codes are transmitted when the system is disarmed.
3 – Pulse Dialing
ON: The alarm system dials telephone numbers using pulse (rotary) dialing.
OFF: The alarm system dials telephone numbers using DTMF (dual tone multi-frequency) touch-tone dialing.
4 – Pulse Dial after 5th Attempt
ON: If DTMF dialing is enabled, the alarm system dials telephone numbers using DTMF dialing for the first 4 attempts. If
unsuccessful, the alarm system switches to pulse (rotary) dialing for the remaining attempts.
OFF: If DTMF dialing is enabled, the alarm system dials telephone numbers using DTMF dialing for all dialing attempts.
5 – Parallel Communications
ON: Parallel communications is enabled. The alarm system attempts to communicate through all available receiver paths
(PSTN and IP (IP=Ethernet or Cellular) at the same time. Once acknowledgment is provided by any of the receivers, the
alarm system communicates the next event. If more than one receiver is configured for PSTN, the backup procedure
described below is followed.
OFF: Parallel communications is disabled. If receiver 1 fails, the alarm system attempts to communicate with the next avail-
able receiver (2-4) in sequence.
Note: When Parallel Communications is enabled it will override Communicator Backup Options, see "[384] Communicator
Backup Options" on page 131 for communicator backup programming.
6 – Alternate Dial
ON: After each failed dialing attempt, the communicator switches to the next backup receiver in the sequence:
Receiver 2 backs up Receiver 1
l
Receiver 3 backs up Receiver 2
l
Receiver 4 backs up Receiver 3
l
This continues until communication is successful or the sequence has been repeated 5 times (depending on the number of
maximum dialing attempts). If all 5 attempts fail, an FTC trouble for the primary phone number is logged. All backup receivers
automatically use the same call directions and format as the primary receiver.
Section 5: Programming
- 129 -