Section 5: Programming
[228] Voice Call Back Time
Default (010) Valid entries are 000 - 255.
[229] Voice Call Back Number
Default ( ) 32 digit phone number.
Valide entries:: 0000000000000001 to FFFFFFFFFFFFFFFE
[422] Integration Identification Number
This section will display the unique 12-digit number assigned to this control panel for the identification when integrated with
third party applications.
[423]Session 1 Integration Access Code
Default (12345678123456781234567812345678) Valid Range is 0000000000000000 - FFFFFFFFFFFFFFFF.
This section is a programmable 32-digit number used for initialization with third party applications.
Note: If integrating with a third party application, this Access Code field must be programmed to a unique number in oder to
secure the connection with 128 bit encryption.
[424] Session 1 SMS Label
Default (11111111)
This section is used to identify the integration session with a third party integrator.
[425] Session 1 Integration Toggle Options 2
The toggle options in this section are used to enable and configure the path used for integration with third party applications.
[1] Integration over USB Default (OFF)
[2] Integration over Cellular Default (OFF)
[3] Integration over Ethernet Default (OFF)
[4]ITv2 Integration Protocol Default (ON)
[426]Session 1 Integration Toggle Options 3
The toggle options in this section are used to determine the polling and notification behavior used for integration with third
party applications.
[1] UDP Polling Default (OFF)
[2] TCP Polling Default (OFF)
[3] Real-time Notification Default (OFF)
[4] Notification Follows Poll Default (OFF)
[5] Firewall IP Default (OFF)
[427] Session 1 Interactive Polling Interval in Seconds
Default (00010) Valid range: 00000-65535
This option controls the polling interval from the alarm panel to the integration interface for the purpose of optimizing data
usage. The shorter the interval, the higher the data usage.
[428] Session 1 Integration Server IP
This section programs the IP address of the third party server. Do not program this section if a domain name is programmed
in setion [431].
[429] Session 1 Integration Notification Port
Default (00372) Valid range: 00000-65535
This section is used to program the TCP Integration port for real time notification
[430] Session 1 Integration Polling Port
Default (00373) Valid range: 00000- 65535
This section is used to program the integration server port. Refer to third party device manual for more information
[431] Session 1 Integration Server DNS
Enter the domain name (up to 32 ASCII characters) as provided by a third-party device. Refer to third party device manual for
more information.