Johnson Controls tyco Power Pro Series Reference Manual page 67

Alarm controller
Table of Contents

Advertisement

A function key can also be programmed to enable/disable this feature. See "Keypad Function Keys" on page 57 for details.
This feature may require an access code. See "[023] System Option 11" on page 114option 7 for details.
The following door chime sounds may be selected:
6 beeps
l
"Bing-Bong"
l
"Ding-Dong"
l
Alarm tone
l
Zone Name -Voice Annunciation (HS2LCDWF keypads only)
l
The above door chime sounds are programmable in section [861]-[876], subsections [101]-[228].
[*][5] Program Access Codes
Use this section to perform the following functions:
press [1] to program user codes 0002-1000, and master code 0001
l
press [2] to enroll a proximity tag
l
press [3] to add a custom label for each user
l
press [4] to assign users to partitions
l
press [5] to program user attributes
l
Assign Access Codes
In order to access alarm system functionality, users must be added to the system. This involves creating a unique access
code and assigning attributes to each user. Access codes are programmed via the [*][5] menu.
Access Code Types
The alarm system provides the following access code types:
Code
Installer
Master
Maintenance
User
Supervisor
Duress
One-time use
+ If section [020] option 7 is on, a user must enter [*][6][Master Code][05] to give the installer permission to access pro-
gramming.
* Can only change master code if section [015] option 6 is off.
** Yes if [023] option 8 is on.
The Installer and Master codes are system codes. They can be changed but not deleted. The other codes are user-defined
and can be added or deleted as necessary. By default, access codes have the same partition and attribute programming as
the code used to program them.
Access codes are either 4, 6 or 8 digits in length, depending on the setting of programming section [041]. Duplicate codes
are not valid.
Note: EN50131-1 compliant systems using more than 100 access codes shall set the access code to 8 digits (section [041],
option 02).
Installer Code
This code provides access to Installer Programming [*][8]. The installer code is only used to gain access to configure the sys-
tem though [*][8] Installer Programming and does not have access to any other function. This code can be programed by the
installer in section [006][001]. The default is 5555 (4-digit), 555555 (6-digit) or 55555555 (8-digit).
EN
Note: For EN50131-1 approved installations the installer code cannot change the master code or any other level 3 codes.
Attempting to access the master code from the installers code generates an error tone from the system.
Section 4: System Operation
Add User
Delete User
No
No
All*
All
No
No
No
No
All but Master
All but Master
No
No
No
No
Arm
Disarm
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1/day
- 67 -
[*][5]
[*][6] [*][8]
No
No
Yes +
Yes
Yes
No
No
No
No
No
No** No
Yes
Yes
No
No
No
No
No
No
No

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the tyco Power Pro Series and is the answer not in the manual?

This manual is also suitable for:

Tyco hs3128Tyco hs3032

Table of Contents