24 Hour Low
ü
057
Temperature
24-Hr Non-
ü
060
Latching Tamper
24-Hr Anti-
061
Masking
Momentary
066
Keyswitch Arm
Maintained
067
Keyswitch Arm
Momentary
068
Keyswitch Disarm
Maintained
069
Keyswitch Disarm
071
Door Bell
072
Push to Set
6.3 End Of Line Resistance
[004] End of Line Resistance
Description
001 – Single EOL
on page 88
002 – Double EOL
003 –Triple EOL
6.4 System Times
[005] System Times
000 – System Area
Description
(3-Digit Decimal)
on page 88
001 – Partition 1 Timer
Section 6: Programming Worksheets
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
CP-01
CP-01
ü
ü
CP-01
CP-01
ü
ü
Alarm (Default 5.6 kΩ)
Valid range: 0.5 kΩ to 28 kΩ (005 to 280)
Alarm (Default 5.6 kΩ)
Valid range: 0.5 kΩ to 15 kΩ (005 -150)
Tamper (Default 5.6 kΩ)
Valid range: 0.5 kΩ to 15 kΩ (005 -150)
Alarm (Default 5.6 kΩ)
Valid range: 0.5 kΩ to 7.5 kΩ (005 -075)
Tamper (Default 5.6 kΩ)
Valid range: 0.5 kΩ to 7.5 kΩ (005 -075)
Bell Cutoff (Default: 004 minutes):
Bell Delay Time (Default: 000 minutes):
Burglary Verification Timer (Default: 060 minutes):
Holdup Verification Timer (Default: 008 hours):
Zone Loop Response Time (Default: 025 x 10 ms):
Automatic Clock Adjust (Default: 060 seconds):
Entry Delay 1 (Default: 030):
Entry Delay 2 (Default: 045):
Exit Delay (Default: 120):
Settle Delay (Default: 010):
- 165 -
Need help?
Do you have a question about the tyco Power Pro Series and is the answer not in the manual?
Questions and answers