[307] Zone Reporting
Zone alarms, tampers and faults are transmitted to the central station using automatic contact ID or SIA formats. Reporting
can be toggled on or off by zone using toggle options 1-6 in subsections 001-128.
See "Reporting Codes" on page 223 for zone reporting code descriptions.
1 - Alarm
2 - Alarm Restore
3 - Tamper
4 - Tamper Restore
5 - Fault
6 - Fault Restore
[308] Event Reporting
System events are transmitted to the central station using automatic contact ID or SIA formats. Reporting can be disabled by
toggle options, programmable in the following sub-sections.
See "Reporting Codes" on page 247 for event code descriptions.
[001] Miscellaneous Alarm 1
The reporting codes in this section are sent to the Alarm & Restore call direction group.
1 – Duress Alarm
Sent when a duress code is used to perform any function on the system.
2 – Opening After Alarm
Sent during disarming if an alarm occurred during the previous armed period.
3 – Recent Closing Alarm
Sent if an alarm occurs within 2 minutes of the exit time expiration (for the first alarm only). Zone alarm transmission delays
do not affect this reporting code.
4/5 – Zone Expander Supervisory Alarm/ Restore
Sent when the system loses communication with the following modules:
Zone Expander Module
l
Keypad with an on-board I/O configured as a zone
l
This reporting code is independent of the general system supervisory code sent to the Alarms and Restores call direction
group.
6 – Burglary Verified
When using Cross Zoning, this reporting code is sent when two crossed zones go into alarm during the cross zone timer.
When using Police Code or sequential detection, this reporting code is sent when any two zones that have the burglary veri-
fication attribute enabled go into alarm. Arming the system resets the zone alarm count for police code or sequential detec-
tion.
7 – Burglary Not Verified
When using Cross Zoning or sequential detection, this reporting code is sent if the cross zone timer is initiated by the first
cross zone alarm, but is not verified by a second alarm before the timer expires.
8 – Alarm Cancel
Sent when a valid access code is entered during the communications cancel window. The central station acknowledges can-
cellation by providing a keypad ringback.
[002] Miscellaneous Alarm 2
1 – Holdup Verified
Sent when the configured Holdup verified conditions have been met.
Note: Not for use with UL/ULC listed installations.
[011] Priority Alarms 1
The reporting codes in this section are sent to the Alarm & Restore call direction group and apply to all system keypads.