Omron OMNUC G Series User Manual page 443

Ac servomotors/servo drives with built-in mechatrolink-ii communications
Hide thumbs Also See for OMNUC G Series:

Advertisement

Pn
Parameter name Setting
No.
040
Reserved
Do not change.
Enables the Emergency Stop Input (STOP).
Emergency Stop
041
Input
0
Setting
1
Sets the logic for the Origin Proximity Input (DEC).
Origin Proximity
0
042
Input Logic
Setting
1
Sets the relationship between polarity of operation
data sent over the network and the direction of
Servomotor rotation.
Operating
043
Direction Setting
0
1
Sets the terminal assignment for Drive Prohibit
Input.
Input Signal
044
0
Selection
1
045
Reserved
Do not change.
046
Reserved
Do not change.
047
Reserved
Do not change.
048
Reserved
Do not change.
049
Reserved
Do not change.
04A
Reserved
Do not change.
04B
Reserved
Do not change.
04C
Reserved
Do not change.
04D
Reserved
Do not change.
04E
Reserved
Do not change.
04F
Reserved
Do not change.
050
Reserved
Do not change.
051
Reserved
Do not change.
052
Reserved
Do not change.
Sets the speed limit for torque control mode.
(The value is an absolute value)
053
Speed Limit
This parameter is limited by the Overspeed
Detection Level Setting (Pn073).
054
Reserved
Do not change.
055
Reserved
Do not change.
056
Reserved
Do not change.
057
Reserved
Do not change.
Soft Start
Sets the acceleration time for speed control mode.
058
Acceleration
Acceleration time [s] from 0 r/min to maximum
Time
speed [r/min] = Set value
Soft Start
Sets the deceleration time for speed control mode.
059
Deceleration
Deceleration time [s] from maximum speed [r/min]
Time
to 0 r/min = Set value
05A
Reserved
Do not change.
Explanation
Disabled
Enabled (alarm code 87 issued on OPEN)
N.C contact (origin proximity detected on
OPEN)
N.O contact (origin proximity detected on
CLOSE)
Sets the reverse direction as the positive
direction (+).
Sets the forward direction as the positive
direction (+).
Sets CN1 pin 19 to POT, CN1 pin 20 to
NOT.
Sets CN1 pin 19 to NOT, CN1 pin 20 to
POT.
2 ms
2 ms
9-1 Parameter Tables
Default
Setting
Unit
Setting
Range
0
---
---
---
1
---
0 to 1
C
1
---
0 to 1
C
1
---
0 to 1
C
0
---
0 to 1
C
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
20000 to
50
r/min
B
20000
0
---
---
---
0
---
---
---
0
---
---
---
0
---
---
---
0
2 ms 0 to 5000 B
0
2 ms 0 to 5000 B
0
---
---
---
Set
value
9
9-10