5-26 User Parameters
Pn
Parameter name Setting
No.
Gain Switch Level
033
Setting (RT)
Gain Switch
Hysteresis
034
Setting (RT)
Position Loop
035
Gain Switching
Time (RT)
5
Reserved
036
037
Reserved
038
Reserved
039
Reserved
03A
Reserved
03B
Reserved
Reserved
03C
03D
Jog Speed
03E
Reserved
Reserved
03F
Reserved
040
Emergency Stop
041
Input Setting
Origin Proximity
Input
042
Logic Setting
5-73
Explanation
Sets the judgment level to switch between Gain 1 and
Gain 2 when the Gain Switch Setting (Pn031) is set to 3,
5, 6, 9, or 10. The unit for the setting depends on the
condition set in the Gain Switch Setting (Pn031).
Sets the hysteresis of the judgment level for the Gain
Switch Level Setting (Pn033) when the Gain Switch
Setting (Pn031) is set to 3, 5, 6, 9, or 10. The unit for the
setting depends on the condition set in the Gain Switch
Setting (Pn031).
This parameter can prevent the position loop gain from
increasing suddenly when the position loop gain and
position loop gain 2 differ by a large amount.
When the position loop gain increases, it takes the
duration of (set value + 1)
Do not change.
Do not change.
Do not change.
Do not change.
Do not change.
Do not change.
Do not change.
Sets the jog operation speed with the Parameter Unit or
CX-Drive.
Note
Jog operation is only available when the network is
not established. Do not try to establish the network
while using jog operation. Otherwise, command
alarm (alarm code 27) will occur.
Do not change.
Do not change.
Do not change.
Enables the Emergency Stop Input (STOP).
Note
If this function is disabled, the response status will
always be 0 (disabled).
0
Disabled.
1
Enabled (alarm code 87 issued on OPEN)
Sets the logic for the Origin Proximity Input (DEC).
0
N.C contact (origin proximity detected on OPEN)
1
N.O contact (origin proximity detected on CLOSE)
166
s.
Default
Setting
Unit
setting
range
600
---
0 to 20000
50
---
0 to 20000
166
20
0 to 10000
s
0
---
---
0
---
---
0
---
---
0
---
---
0
---
---
0
---
---
0
---
---
200
r/min
0 to 500
0
---
---
0
---
---
0
---
---
1
---
0 to 1
1
---
0 to 1
B
B
B
---
---
---
---
---
---
---
B
---
---
---
C
C