3-4 Cable and Connector Specifications
XW2D-20G6 (M3 screw terminal block)
3
 Dimensions
Precautions
for Correct Use
Round Crimp Terminals
3.2-mm dia.
Round Crimp Terminals
The diagram on the next page shows a typical connection between a host device and the Servo
Drive using a MECHATROLINK-II communications cable.
3-81
79
57
 When using crimp terminals, use crimp terminals with the following
dimensions.
 When connecting wires and crimp terminals to a terminal block, tighten
them with a tightening torque of 0.7 N·m.
Fork Terminals
5.8 mm max.
Applicable Crimp Terminals
Fork Terminals
Two, 4.5 dia.
3.2 mm
5.8 mm max.
Applicable Wires
AWG22-16
1.25-3
(0.3 to 1.25 mm
AWG22-16
1.25Y-3
(0.3 to 1.25 mm
(39.1)
17.6
39
2
)
2
)