Figure9-4 : Microsoft Azure Subscribe Topic Setting Page - ICP DAS USA PMD Series User Manual

Power meter concentrator
Hide thumbs Also See for PMD Series:
Table of Contents

Advertisement

ICP DAS PMC-523x/PMC-224x/PMD Series User Manual
xiii In the "Variable Name" field, user can input the name of the variable
which is defined in the message of the Subscribe Topic. After
completing the settings, click the "Add" button to add the variable. For
the message the PMC/PMD receives from Microsoft Azure is based on
JSON format, the PMC/PMD will get the corresponding value of the
variable from the received message. The following is an example of a
message the PMC/PMD receives:
{
}
In this example, the "Target" and "Action" variable setting will be
performed first. Each time when the PMC/PMD receives the message,
it will retrieve the corresponding value of the "Target" and "Action"
variables from the message. The value of the variables can be used in
the evaluation criteria of IF Condition to trigger THEN/ELSE Action
for logic operation.
xiv After completing all settings on the Microsoft Azure Setting Page,
please click "Save" button to save the settings. After downloading the
settings to PMC/PMD, PMC/PMD will initiate the connection to the
Microsoft Azure, and start the data communication with the Microsoft
Azure.
Figure9-4 :
Microsoft Azure Subscribe Topic setting page
"Target":"door",
"Action":"open",
"Timestamp":"2016/10/17 15-17-22"