Improving Print Quality; Cleaning The Roller Waste Collector And Inspecting The Roller Scraper - Stratasys Objet500 User Manual

3d printing system
Hide thumbs Also See for Objet500:
Table of Contents

Advertisement

Objet500 User Guide
Improving Print Quality
If you suspect that print quality is poor, perform the Pattern Test (see "Pattern 
Test" on page 6-35). If the results are poor, use the following procedure to 
improve print quality.
If the results of the last pattern test are poor:
1.  From the Options menu, select Purge Sequence, or press F4.
2.  In the confirmation dialog box, click Yes.
3.  Repeat the purge sequence.
4.  Perform the pattern test.
If the results of the pattern test are still poor:
1.  Manually clean the print heads (see "Cleaning the Print Heads and the 
2.  Perform the purge sequence.
3.  Perform the pattern test.
If the results of the pattern test are still poor:
1.  Carefully clean the print heads again, making sure there is no residue left on 
2.  Perform the purge sequence.
3.  Perform the pattern test.
If the results of the pattern test are still poor:
➢  Optimize the print heads and replace faulty print heads, if necessary (see 
 
Cleaning the Roller Waste Collector and Inspecting the Roller Scraper
The roller waste collector removes waste material scraped from the roller. 
Suction removes this waste to the printer's waste container.
This assembly should be cleaned weekly to prevent a blockage in the tubes 
leading to the waste container, so that waste material does not overflow into the 
printer.
DOC-07027 Rev. I
The print heads are purged of Model and Support material, and the wiper 
removes excess material from them.
Roller" on page 6-29).
them.
"Optimizing (Calibrating) Print Heads" on page 6-47).