Objet500 User Guide
External UV Meter
The following steps apply when using a stand-alone UV meter. This section does 
not apply when using the Stratasys UV sensor box connected to the printer.
1.  When the following screen appears, open the printer and place the UV 
2.  Lead the cable out of the printer so that you can close the printer, and tape it 
3.  Close the printer, while checking that the sensor does not move out of 
4.  Set the UV meter to measure mJ/cm2.
5.  Set the range on the meter to 2,000.
6.  Connect the cable from the sensor to the UV meter. 
7.  Turn on the UV meter, and wait until "0 0 0.0" appears on the display.
8.  In the wizard screen, confirm that the sensor is positioned correctly, and click 
Continue with "UV Measurement               "  on the next page.                
DOC-07027 Rev. I
sensor (probe) at the rear edge of the tray, in the center.
Figure 6-98    Sensor placement screen
down to make sure that it does not interfere with the moving print block.
Figure 6-99    Correct UV-sensor placement
position.
Next.
6 Operating and Maintaining the Printer
 
6-70