Optimizing (Calibrating) Print Heads
The condition of the print heads directly affects the quality of printed models. To 
maintain optimum printing, you should routinely test the print heads, and calibrate 
them to the best working configuration possible by running the Head 
Optimization wizard every 300 hours of printing.
You also need to calibrate the print heads in these cases:
• after replacing Vero with Digital ABS or Agilus30 Model materials (and the 
• after changing the type of Support material (SUP705/706)
• after replacing the Support material with cleaning fluid (and the reverse)
During this procedure, you place a scale on the build tray and connect it to the 
printer. Printing material (resin) is jetted from each head and its weight is 
automatically recorded and the wizard determines how to optimize the print 
heads. 
If, during the optimization process, the wizard determines that a print head is 
faulty—or that it is negatively affecting layer uniformity with the current head 
configuration—the wizard instructs you to replace it. If this happens, you can 
continue the wizard to replace the print head, or abort the wizard, to replace the 
head at another time. 
Run the Head Optimization wizard every 300 hours of printing or whenever 
the condition of print heads is negatively affecting the quality of printed 
models, or if you suspect that there is a problem with one or more of the print 
heads.
Note:  Allow at least 40-50 minutes per mode   f or performing this procedure (not 
including time required for replacing faulty print heads). To accurately test and 
calibrate print heads, they must be clean. If necessary, run the Head Cleaning 
wizard before beginning this procedure.
To test and calibrate the print heads:
1.  Prepare—
2.  Check that there is a material cartridge loaded in the M3 slot. If necessary, 
DOC-07027 Rev. I
reverse)
❒  disposable cleaning gloves (any clean, powder-free protective gloves)
❒  pink paper
❒  the Missing Nozzles ruler
❒  the scale supplied for use in the Head Optimization wizard
Important:  Before beginning this procedure, ensure that the scale is 
calibrated and at least partially charged. 
insert a cartridge that contains different material than is loaded in the other 
slots.
Note:  The Head Optimization wizard will not operate if the M3 cartridge slot 
is empty.