Objet500 User Guide
To clean the roller waste collector:
1.  Prepare—
2.  From the Option menu, select Go to Head Inspection Position.
3.  Put on the gloves.
4.  Remove the right UV-lamp assembly:
DOC-07027 Rev. I
❒  M2.5 and M2 Hex (Allen) keys
❒  disposable cleaning gloves
❒  90% isopropanol (IPA—isopropyl alcohol) or ethanol (ethyl alcohol)
❒  cleaning cloth
❒  cotton swabs (Q-tips or similar)
❒  mirror
❒  flashlight
a.  Disconnect the UV power cable and the fan power cable.
Figure 6-39    Disconnecting the right UV assembly
b.  Remove the screw that secures the right UV lamp, and then pull and lift 
up the UV lamp.