Objet500 User Guide
The entire print-head replacement procedure takes 75—90 minutes, and
consists of the following phases:
A. Identifying the head(s) needing replacement.
B. Preparing the print block for head replacement.
C. Removing the defective print head.
D. Installing a new print head.
E. Optimizing the print heads (done automatically by the wizard).
F. Performing head alignment.
To replace a print head:
1. Prepare—
2. Start the Head Optimization wizard from the Options menu (see the figure on
3. In the opening wizard screen, click Next to begin.
4. Read the conditions, select I Agree and click Next.
DOC-07027 Rev. I
This is normally done by the Head Optimization wizard. Otherwise, evidence
of physical damage to the head surface or a malfunction message indicates
which head needs replacing.
This is done automatically when you run the wizard.
❒ replacement print head(s)
❒ 90% isopropanol (IPA—isopropyl alcohol) or ethanol (ethyl alcohol)
❒ disposable cleaning gloves (use clean, powder-free gloves)
❒ lint-free cleaning cloths
❒ a mirror
❒ a 5-mm flat-head screwdriver or a 3-mm hex (Allen) key (depending on
the type of print block)
❒ the scale supplied for use in the Head Optimization wizard (Weight Test)
❒ the Missing Nozzles ruler
Important: Make sure that you have these items and that the scale is
calibrated and at least partially charged before continuing.
page 6-47).
The Wizard Conditions screen appears.
6 Operating and Maintaining the Printer
6-56