The entire print-head replacement procedure takes 75—90 minutes, and 
consists of the following phases: 
A.  Identifying the head(s) needing replacement. 
B.  Preparing the print block for head replacement.
C.  Removing the defective print head. 
D.  Installing a new print head.
E.  Optimizing the print heads (done automatically by the wizard).
F.  Performing head alignment.              
 
To replace a print head:
1.  Prepare—
2.  Start the Head Optimization wizard from the Options menu (see the figure on 
3.  In the opening wizard screen, click Next to begin.
4.  Read the conditions, select I Agree and click Next.
DOC-07027 Rev. I
This is normally done by the Head Optimization wizard. Otherwise, evidence 
of physical damage to the head surface or a malfunction message indicates 
which head needs replacing.
This is done automatically when you run the wizard.
❒  replacement print head(s)
❒  90% isopropanol (IPA—isopropyl alcohol) or ethanol (ethyl alcohol)
❒  disposable cleaning gloves (use clean, powder-free gloves)
❒  lint-free cleaning cloths
❒  a mirror
❒  a 5-mm flat-head screwdriver or a 3-mm hex (Allen) key (depending on 
the type of print block)
❒  the scale supplied for use in the Head Optimization wizard (Weight Test)
❒  the Missing Nozzles ruler
Important:  Make sure that you have these items and that the scale is 
calibrated and at least partially charged before continuing.
page 6-47).