Objet500 User Guide
To test and calibrate UV lamp radiation:
1. Start the UV Calibration Wizard from the Options menu.
2. In the following screen, select Calibrate UV Intensity to adjust the lamp's
3. In the following screen, select the UV sensor and measuring device to be
UV Measuring Device
When you use the Stratasys UV sensor box (TOL-03005-S), you connect it to
the printer. The wizard automatically measures and calibrates the UV
radiation.
If you use a stand-alone UV radiation meter, you need to manually enter the
readings from the meter in the wizard screens.
DOC-07027 Rev. I
radiation level to the acceptable range.
Figure 6-90 UV Test/Calibration selection
used.
Figure 6-91 UV device selection
6 Operating and Maintaining the Printer
6-66