To test and calibrate UV lamp radiation:
1.  Start the UV Calibration Wizard from the Options menu.
2.  In the following screen, select Calibrate UV Intensity to adjust the lamp's 
3.  In the following screen, select the UV sensor and measuring device to be 
UV Measuring Device
When you use the Stratasys UV sensor box (TOL-03005-S), you connect it to 
the printer. The wizard automatically measures and calibrates the UV 
radiation.
If you use a stand-alone UV radiation meter, you need to manually enter the 
readings from the meter in the wizard screens.
DOC-07027 Rev. I
radiation level to the acceptable range.
Figure 6-90    UV Test/Calibration selection
used.
Figure 6-91    UV device selection