Objet500 User Guide
Warning: Broken UV lamp hazard
UV lamps contain mercury. Deal with broken lamps with caution.
l
l
l
l
17. I nsert the UV reflector unit into the housing, next to the print block.
18. R eplace the UV lamp cover by inserting it into the slot on the bottom of the
DOC-07027 Rev. I
Ventilate the room thoroughly.
Use protective gloves when collecting mercury and lamp components.
Remove spilled mercury with a method that prevents the generation of
mercury vapor, such as a syringe, packing tape or paper.
Place the broken lamp, mercury and contaminated materials in an air-tight,
non-metallic container.
Figure 6-121 Print block and UV lamp assembly, showing correct
placement of black strip
housing, and tighten the securing screw on top.
Figure 6-122 Replacing the UV lamp cover
6 Operating and Maintaining the Printer
6-81