9.21 PBX Configuration—[1-1] Configuration—Slot—Extension—Card Property
Feature Guide References
2.13.3 Call Splitting
Flash Timing - Min.
Specifies the minimum length that a signal sent from an SLT must be for the PBX to recognise it as a hookswitch
flash signal.
Value Range
8 ´ n (n=3–63) ms
Flash Timing - Range
Specifies the maximum length that a signal sent from an SLT can be for the PBX to recognise it as a hookswitch
flash signal.
Value Range
8 ´ n (n=3–191) ms
DTMF-R STD Detection Time
Specifies the minimum length that a DTMF tone must be for the PBX to recognise it as a DTMF tone.
Value Range
2 ´ n (n=1–31) ms
SLT Power Supply
Selects the voltage that enables an SLT to activate the Message Waiting lamp. When an MCSLC card is
installed, the value for this setting is fixed at "85 V".
Value Range
85 V, 145 V
Feature Guide References
2.20.1 Message Waiting
APT/SLT Parallel Connection
Enables an SLT connected in parallel to an APT to ring with the APT for calls.
Value Range
Disable, Enable
Feature Guide References
2.11.10 Parallelled Telephone