CAUTION
① The DI (Option) consists of a combination of 3 Digital inputs. The alarm output consists of 6-Relay
output (Normally open).
② Relay No.1 is a common output of paper empty sensor (Option) and alarm.
4.3.2 Alarm Output Wiring Procedure
Wire the Alarm output refer to Fig.4.8.
1A 1C
4.3.3 DI Wiring Procedure
Wire the DI refer to Fig.4.9.
1A
4+
B
1+
B
Fig. 4.9 DI/Alarm Output Wiring
2A 2C
3A 3C
4A 4C 5A 5C
1C
Relay No.1
(Normally open)
1A
Fig. 4.8 Alarm Output Wiring
1C
2A
2C
3A
3C
4A
4C
5A
4-
6-
4
5+
5-
5
6+
B
A
B
A
B
B
B
1-
1
2-
2
3+
3-
2+
B
A
B
B
B
B
A
―21―
L
N
6A 6C
+
-
6-Relay output
6C
Relay No.6
(Normally open)
6A
L
N
5C
6A
6C
+
-
6
DI
DI
DI
DI
A
COM
3
2
1
3
TD
RD
SG
A
DI1
DI2
DI3
DI.COM
(COMMON for DI1 to DI3)
HXPRM10mnCT001E