Recommended Test Equipment (Oscilloscope); Recommended Test Equipment (Oscilloscope) - Agilent Technologies 1670G Series Service Manual

Logic analyzers
Hide thumbs Also See for 1670G Series:
Table of Contents

Advertisement

General Information

Recommended test equipment (oscilloscope)

Recommended test equipment (oscilloscope)

Equipment Required
Equipment
Critical Specifications
Signal Generator
Frequency: 1 - 500 MHz at approx.
170 mV RMS
Output Accuracy: ± 1 dB
1 MHz time base accuracy 0.25 ppm
Range: −35.000 to +35.000 Vdc, ±1 mV
DC Power Supply
Digital Multimeter
0.1 mV resolution
Accuracy: better than 0.005%
Resistance measurement: better than
0.25% accuracy
1 - 250 MHz ±3% accuracy
Power Meter/Sensor
Power Splitter
Outputs differ by <0.15 dB
BNC (m)(f), 0.18 µF, ±200 V
Blocking Capacitor
BNC Shorting Cap
Adapter
BNC (f)(f) (UG-914/U)
Adapter
BNC(f)-to-Dual Banana Plug
Adapter
Type N(m)-to-BNC(f)
BNC Tee
BNC (m)(f)(f)
Cable
Type N(m-to-m) 24-inch
50 Ω BNC (m-to-m) 48-inch
Cable
50 Ω BNC (m-to-m) 9 inch
Cable (2)
*P = Performance Tests
C = Calibration
1–10
Recommended
Use*
Model/Part
8656B Option 001
P
3245A Option 002
P
3458A
P
436/8482A
P
11667B
P
10240B
P
1250-0074
P
1250-0080
C
1251-2277
P
1250-0780
P
1250-0781
P,C
11500B
P
10503A
P, C
10502A
C