Testing Performance

To test the bandwidth (oscilloscope)

To test the bandwidth (oscilloscope)
Testing the bandwidth verifies the performance of the following specification:
Bandwidth
This test verifies the bandwidth (dc coupled) of the instrument from dc to 500 MHz.
Equipment Required
Equipment
Signal Generator
Power Meter/Sensor
Power Splitter
Cable
Adapter

Set up the equipment

Turn on the equipment required and the logic analyzer. Let them warm up for 30
minutes if you have not already done so.
3–72
Critical Specifications
1 - 250 MHz at approximately 170 mV rms
1 - 250 MHz ± 3% accuracy
Outputs differ by <0.15 dB
Type N (m)(m) 24-inch
Type N (m) to BNC (f)
Recommended
Model/Part
8656B
436/8482A
11667B
11500B
1250-0780