10.12 N: Special Adjustment; N1: Hunting Prevention; N2: Auto Freq Regulator (Afr) - YASKAWA CR700 Technical Manual

Hide thumbs Also See for CR700:
Table of Contents

Advertisement

10.12 n: Special Adjustment

n1: Hunting Prevention

No.
Name
(Hex.)
n1-01
Hunting Prevention
Selection
(0580)
n1-02
Hunting Prevention Gain
Setting
(0581)
Expert
n1-03
Hunting Prevention
Time Constant
(0582)
Expert
n1-05
Hunting Prevent Gain in
Reverse
(0530)
Expert
n1-08
Current Detection
Method
(1105)
Expert
n1-13
DC Bus Stabilization
Control
(1B59)
Expert
n1-14
DC Bus Stabilization
Time
(1B5A)
Expert
n1-15
PWM Voltage Offset
Calibration
(0BF8)
Expert
n1-16
Hunting Prevention High
Fc Gain
(0BFB)
n1-17
Hunting Prevent High Fc
Filter
(0BFC)
Expert
n1-20
Voltage Calibration
Duration
(1588)
Expert

n2: Auto Freq Regulator (AFR)

No.
Name
(Hex.)
n2-01
Automatic Freq
Regulator Gain(F)
(0584)
n2-02
Automatic Freq
Regulator Time 1
(0585)
n2-03
Automatic Freq
Regulator Time 2
(0586)
n2-06
Automatic Freq
Regulator Gain(R)
(1567)
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to prevent hunting.
0 : Disable
1 : Enabled
2 : Enabled (High Carrier Frequency)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the performance of the hunting prevention function. Usually it is not necessary to
change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the primary delay time constant of the hunting prevention function. Usually it is
not necessary to change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the performance of the hunting prevention function. This parameter adjusts
Reverse run. Usually it is not necessary to change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets how the drive decreases the motor vibration that is caused by leakage current.
Usually it is not necessary to change this parameter.
0 : 2-Phases
1 : 3-Phases
V/f
CL-V/f
OLV
CLV
AOLV
Sets the oscillation suppression function for the DC bus voltage.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Adjusts the responsiveness of the oscillation suppression function for the DC bus
voltage. Set n1-13 = 1 [DC Bus Stabilization Control = Enabled] to enable this
parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the calibration method that the drive uses to decrease torque/current ripple.
0 : No Calibration
1 : One Time Calibrate at Next Start
2 : Calibrate Every Time at Start
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for the hunting prevention function. This parameter functions best with a
high carrier frequency. Usually it is not necessary to change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of the hunting prevention function. Usually it is not necessary to
change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the calibration time at start. Usually it is not necessary to change this parameter.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the AFR function for forward run as a magnification value. Usually it is
not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant that sets the rate of change for the AFR function. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant to determine the variation in speed of the AFR function. Use this
parameter during regeneration. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the AFR function for reverse run as a magnification value. Usually it is
not necessary to change this setting.
10.12 n: Special Adjustment
Default
Ref.
(Range)
Determined by o2-04
769
(0 - 2)
1.00
769
(0.00 - 2.50)
Determined by o2-04
769
(0 - 500 ms)
0.00
769
(0.00 - 2.50)
0
770
(0, 1)
0
770
(0, 1)
100.0 ms
770
(50.0 - 500.0 ms)
Determined by A1-02
770
(0 - 2)
Determined by o2-04
770
(0.00 - 2.50)
500 ms
771
(0 - 1000 ms)
50 ms
771
(10 - 500 ms)
Default
Ref.
(Range)
1.00
771
(0.00 - 10.00)
50 ms
771
(0 - 2000 ms)
750 ms
772
(0 - 2000 ms)
1.00
772
(0.00 - 10.00)
10
521

Advertisement

Table of Contents
loading

Table of Contents