11.6 d: Reference Settings

11.6

d: Reference Settings

d1: Speed Reference

No.
Name
(Hex.)
d1-01
Speed Reference 1
(0280)
RUN
d1-02
Speed Reference 2
(0281)
RUN
d1-03
Speed Reference 3
(0282)
RUN
d1-04
Speed Reference 4
(0283)
RUN
d1-05
Speed Reference 5
(0284)
RUN
d1-06
Speed Reference 6
(0285)
RUN
d1-07
Speed Reference 7
(0286)
RUN
d1-08
Speed Reference 8
(0287)
RUN
d1-18
Spd Ref Sel Mode
(02C0)
d1-19
Nominal Speed
(02C1)
RUN
d1-20
Intermed Speed 1
(02C2)
RUN
d1-21
Intermed Speed 2
(02C3)
RUN
d1-22
Intermed Speed 3
(02C4)
RUN
d1-23
Releveling Speed
(02C5)
RUN
d1-24
Inspect Oper Spd
(02C6)
RUN
d1-25
Rescue Oper Spd
(02C7)
RUN
d1-26
Leveling Speed
(02C8)
RUN
244
Description
V/f
OLV
Sets the Speed reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
Sets the speed reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
Sets the Speed reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
Sets the Speed reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
Sets the Speed reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
Sets the Speed reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
Sets the Speed reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
Sets the Speed reference in the units from o1-03 [Frequency Display Unit Selection].
V/f
OLV
Sets the priority of the speed reference digital inputs.
If d1-18 = 0, multi-speed references d1-01 to d1-08 are used.
If d1-18 = 1, values from parameters d1-19 to d1-23 have priority.
0 : Use Multi-Speed references d1-01 to d1-08
1 : High speed reference has priority
2 : Leveling speed reference has priority
V/f
OLV
Sets the speed reference when multi-function input "Nominal Speed" is on.
V/f
OLV
Sets the speed reference when intermediate speed 1 is selected by digital inputs.
V/f
OLV
Sets the speed reference when intermediate speed 2 is selected by digital inputs.
V/f
OLV
Sets the speed reference when intermediate speed 3 is selected by digital inputs.
V/f
OLV
Sets the speed reference when releveling speed is selected by digital inputs.
V/f
OLV
Sets the speed reference when inspection speed is selected by digital inputs.
V/f
OLV
Sets the speed reference when rescue speed is selected by digital inputs.
V/f
OLV
Sets the speed reference when leveling speed is selected by digital inputs.
Default
(Range)
0.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
1
(0 - 2)
50.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
0.00 Hz
(0.00 - 120.00 Hz)
30.00 Hz
(0.00 - 120.00 Hz)
5.00 Hz
(0.00 - 15.00 Hz)
4.00 Hz
(0.00 - 120.00 Hz)
YASKAWA SIEPYEULA5001C LA500 Technical Manual
Ref.
296
296
296
296
296
296
297
297
297
297
297
297
298
298
298
298
298