One-Touch Tuning Stop (Obj. 2D52H)]; [One-Touch Tuning Stop (Obj. 2D52H: 00H)]; One-Touch Tuning Clear (Obj. 2D53H)]; [One-Touch Tuning Clear (Obj. 2D53H: 00H)] - Mitsubishi Electric MR-J5-G-N1 User Manual

Hide thumbs Also See for MR-J5-G-N1:
Table of Contents

Advertisement

9.65

[One-touch tuning Stop (Obj. 2D52h)]

[One-touch tuning Stop (Obj. 2D52h: 00h)]

Data Type
Access
U16
RW
Supported firmware version
ECT
A5
Description
Set a one-touch tuning stop command. To check whether the setting is reflected, read [One-touch tuning mode (Obj. 2D50h)].
• 1EA5h: Stops one-touch tuning.
• Other than 1EA5h: Triggers a parameter out of range error.
When the object is read, whether one-touch tuning can be stopped is returned.
Bit
Description
0
0: One-touch tuning can be stopped with the command. (One-touch tuning in progress)
1: One-touch tuning cannot be stopped with the command. (One-touch tuning not in progress)
1 to 31
9.66

[One-touch tuning Clear (Obj. 2D53h)]

[One-touch tuning Clear (Obj. 2D53h: 00h)]

Data Type
Access
U16
RW
Supported firmware version
ECT
A5
Description
The servo parameter that was changed in one-touch tuning is returned to the value before the change. To check whether the
setting is reflected, read [One-touch tuning mode (Obj. 2D50h)].
• 0000h: Restores to factory setting
• 0001h: Restores to the value from before one-touch tuning
When the object is read, whether the servo parameter that changed in one-touch tuning can be restored to the value before
the change is returned.
Bit
Description
0
0: Cannot be restored to factory setting with the command. (One-touch tuning in progress)
1: Can be restored to factory setting with the command. (One-touch tuning not in progress)
1
0: Cannot be restored to the value before one-touch tuning with the command. (One-touch tuning has not been performed for the axis,
one-touch tuning is in progress for the axis, or an incorrect axis was selected.)
1: Can be restored to the value before one-touch tuning with the command. (One-touch tuning executed)
2 to 31
9 Manufacturer Specific Control Object
138
9.65 [One-touch tuning Stop (Obj. 2D52h)]
Mapping
Default
Impossible
0000h
Mapping
Default
Impossible
0000h
Range
Units
0000h, 1EA5h
Range
Units
0000h to 0001h
Save
Parameter
Impossible
Save
Parameter
Impossible

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5w-g-n1Mr-j5-gMr-j5w-g