[Minimum Cycle Time (Obj. 1C33h: 05h)]

Data Type
Access
U32
RO
Supported firmware version
ECT
A5
Description
The minimum communication cycle is returned.
Servo amplifier
MR-J5-_G-_N1
MR-J5D1-_G_-_N1
MR-J5W_-_G-N1
MR-J5D2-_G_-_N1
MR-J5D3-_G_-_N1

[Calc and Copy Time (Obj. 1C33h: 06h)]

Data Type
Access
U32
RO
Supported firmware version
ECT
A5
Description
The minimum value of the delay time from data inputting to transmitting is returned. The received value varies depending on
the setting of the communication cycle.
5 Sync Manager Communication Objects
68
5.5 [SM input parameter (Obj. 1C33h)]
Mapping
Default
Impossible
Minimum communication cycle
125000
250000
Mapping
Default
Impossible
Range
Units
ns
Range
Units
ns