[One-touch tuning Error Code (Obj. 2D54h)]

[One-touch tuning Error Code (Obj. 2D54h: 00h)]

Data Type
Access
U16
RO
Supported firmware version
ECT
A5
Description
An error code of the one-touch tuning is returned.
Refer to "One-touch tuning error" in the following manual.
MR-J5 User's Manual (Adjustment)
0000h: Properly completed
C000h: Tuning canceled
C_01h: Overshoot exceeded
C_02h: Servo-off during tuning
C_03h: Control mode error
C_04h: Time-out
C_05h: Load inertia moment ratio misestimated
C_06h: Servo amplifier built-in command start error
C_07h: Servo amplifier built-in command generation error
C_08h: Stop signal
C_09h: Parameter
C_0Ah: Alarm
C00Fh: One-touch tuning disabled
9.68

[Software reset (Obj. 2D5Fh)]

[Software reset (Obj. 2D5Fh: 00h)]

Data Type
Access
U16
RW
Supported firmware version
ECT
C4
Description
Writing "1EA5h" performs the software reset. Writing a value other than "1EA5h" triggers a parameter out of range error.
When the object is read, "0000h" is returned.
Mapping
Default
Impossible
Mapping
Default
Impossible
0000h
Range
Units
Refer to the
following.
Range
Units
0000h to FFFFh
9 Manufacturer Specific Control Object
9.67 [One-touch tuning Error Code (Obj. 2D54h)]
Save
Parameter
Impossible
Save
Parameter
Impossible