[Synchronization Types supported (Obj. 1C33h: 04h)]
Data Type
Access
U16
RO
Supported firmware version
ECT
A5
Description
Bit 0: FreeRun supported
Bit 1: Synchronous supported (not supported)
Bit 2 to Bit 4: DC Type supported
000 = No DC (not supported)
001 = DC Sync0
010 = DC Sync1 (not supported)
100 = Subordinated Application with fixed Sync0 (not supported)
Bit 5 to Bit 6: Shift settings
00 = No Output Shift supported
01 = Output Shift with local time (not supported)
10 = Output Shift with Sync1 (not supported)
Bit 7 to Bit 9: Reserved
Bit 10: Delay Time should be measured (not supported)
Bit 11: Delay Time is fix. (not supported)
Bit 12 to Bit 13: Reserved
Bit 14: Dynamic Cycle Times (not supported)
Bit 15: Reserved
Mapping
Default
Impossible
0005h
Range
Units
0005h (fixed)
5 Sync Manager Communication Objects
5.5 [SM input parameter (Obj. 1C33h)]
Save
Parameter
Impossible
5
67