7.8
[Reset alarm (Obj. 2A46h)]
[Reset alarm (Obj. 2A46h: 00h)]
Data Type
Access
U16
RW
Supported firmware version
ECT
A5
Description
The alarm that has occurred in the servo amplifier is cleared.
Writing "1EA5h" resets an alarm. Any value other than "1EA5h" is invalid.
When the object is read, "0000h" is returned.
7.9
[Converter Alarm No. (Obj. 2A47h)]
[Converter Alarm No. (Obj. 2A47h: 00h)]
Data Type
Access
U32
RO
Supported firmware version
ECT
C0
Description
The number of the alarm that has occurred on the converter unit side is returned.
If no alarm has occurred on the converter unit side, or if serial communication with the converter unit is not performed,
"00000000h" is returned.
Mapping
Default
Impossible
0000h
Mapping
Default
Impossible
00000000h
Range
Units
0000h to FFFFh
Range
Units
00000000h to
000000FFh
7.8 [Reset alarm (Obj. 2A46h)]
Save
Parameter
Impossible
Save
Parameter
Impossible
7 Alarm Objects
7