20.3

[Torque offset (Obj. 60B2h)]

[Torque offset (Obj. 60B2h: 00h)]

Data Type
Access
I16
RW
Supported firmware version
ECT
A5
Description
Set the torque offset.
Mapping
Default
RxPDO
0
Range
Units
-32768 to 32767
0.1 % (with rated
torque being 100
%)
20 Cyclic Synchronous Position Mode Objects
20.3 [Torque offset (Obj. 60B2h)]