YOKOGAWA WT3002E User Manual page 34

Precision power analyzer
Hide thumbs Also See for WT3002E:
Table of Contents

Advertisement

1.10 Specifications of the Motor Evaluation Function
Symbols and Determination of Motor Evaluation Measurement Functions
Measurement Functions
during Normal
Measurement
Rotating
speed
Torque
Synchronous
speed
Slip
[%]
Motor
output
Set the efficiency equation or user-defined function to determine the motor efficiency and total efficiency.
1-26
When the type of input signal from the revolution sensor is DC voltage (analog signal)
Input voltage from the revolution sensor • Scaling factor
Scaling factor: Number of rotations per volt of input voltage
When the type of input signal from the revolution sensor is pulse count
Number of input pulses from the revolution sensor per minute
Scaling factor: When the signal of the gear ratio or revolution sensor is a
converted signal, you can specify the gear ratio for the scaling factor to
determine the rotating speed before the gear change.
When type of input signal from the torque meter is DC voltage (analog signal)
Scaling factor
Scaling factor: torque per volt of input voltage
When the type of input signal from the torque meter is pulse count
(Torque pulse coefficient • pulse frequency + torque pulse offset) • scaling factor
Torque pulse coefficient and torque pulse offset: Calculated in this instrument
from the torque values [N·m] at two points corresponding to the upper and
lower limits of frequency.
Scaling factor: Normally, use the value of 1. When using a unit other than N·m,
set the conversion ratio of the unit.
120 Frequency of the frequency measurement source (Hz)
• The unit of synchronized speed is fixed to "min
• Normally, the frequency measurement source is set to the voltage or current
that is supplied to the motor. The synchronized speed may not be
determined correctly if a different signal is specified.
SyncSp – Speed
SyncSp
2
Speed
Torque
60
Pm
When the unit of speed is "min
scaling factor is 1, the unit of motor output Pm is "W."
Method of Determination, Equation
Number of pulses per rotation
input voltage from the torque meter
Motor's number of poles
100
Scaling factor
–1
(or rpm)," the unit of torque is "N·m," and the
• Scaling factor
–1
(or rpm)."
IM WT3001E-51EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wt3001eWt3003eWt3004eWt3000e

Table of Contents