Basic Commands
Maintenance port characteristics are: 8 bits/1 start/1 stop/no parity.
Baud rates are: 300, 600, 1200, 2400, 4800, 9600, or 19,200.
Maintenance commands do not require the ESC sequence used with
CDE commands.
Entering Command Sequences
Maintenance commands are entered by selecting a softkey from a
menu, and then selecting another softkey from the subsequent menu.
Start all maintenance sequences from the Maintenance screen.
Press the DELETE key to delete the most recently entered softkey or
device number.
At the end of a command sequence, press ENTER.
Press the CANCEL softkey at any time to exit the current operation
without committing (saving) any changes, or press the ENTER softkey,
when it is available, to commit changes or initiate an activity.
For example, to show time:
Select SYSTEM from the Maintenance screen.
Select SHOW from the System screen.
Select TIME from the Show screen.
Select ENTER from the Show screen or Press ENTER at the
keyboard.
Logging In
1. Hit RETURN 4 times within 1 second,
(2 times for SX-200 LIGHT/DIGITAL) and then follow the prompts.
2. Select a Terminal Type.
3. Select an Application.
4. Enter your username.
5. Enter your password.
Maintenance Commands
231