Programming A Non-Dial-In Trunk - Mitel SX-200 EL Technician's Handbook

Hide thumbs Also See for SX-200 EL:
Table of Contents

Advertisement

Technician's Handbook
The following table shows how Analog Networking and Call-by-Call
informationl co-exist in the Modified Digit Table.
Entry
01
In the "Digits to be Inserted" field, the definition of characters are:
*4
No SMDR for further modified digits
000
Call-by-Call digits, (speech, default O/G, clid)
*6
Send caller id (DID to network)
*4
Start SMDR again for further modified digits
13. Complete ARS programming
ARS programming must match with the service selection
n
programming that is entered through the ISDN Maintenance
Administration Tool (IMAT) computer.
Refer to the IMAT online Help file for information about
programming the IMAT database.

Programming a Non-Dial-In Trunk

1. Form 01, System Configuration
Program a trunk card that meets the trunk type requirements.
n
2. Form 13, Trunk Circuit Descriptor
Create a trunk circuit descriptor that corresponds to the type of
n
trunk that you are programming.
3. Form 03, Class of Service
Assign trunk options only.
n
116
Quantity to
Digits to be
Delete
1
Inserted
*4000*6*4
ISDN CxC and DID
Comments

Advertisement

Table of Contents
loading

This manual is also suitable for: