Configuration Rules for the Control Triple FIM Carrier Card
The Control Triple FIM Carrier Card can only be installed in a
SX-200 EL system.
Slot 10 first on-board FIM interfaces to first peripheral
n
cabinet (Bay 2)
Slot 10 second on-board FIM interfaces to second peripheral
n
cabinet (Bay 3)
Slot 10 add-on FIM interfaces to fifth peripheral cabinet (Bay 6)
n
Slot 11 first on-board FIM interfaces to third peripheral
n
cabinet (Bay 4)
Slot 11 second on-board FIM interfaces to fourth peripheral
n
cabinet (Bay 5)
Slot 11 add-on FIM interfaces to sixth peripheral cabinet (Bay 7)
n
Configuration Rules for the Control Triple CIM Card
The Control Triple CIM card has a S1 switch that sets the card as a triple
interface card (switch 4 closed) or a double interface card (switch 4
opened).
If the S1 switch on the Control Triple CIM card is set to take two circuits
(emulates the control dual carrier card), the following positions are hard
coded in the software:
Slot 10 embedded CIM #1 interfaces to Bay 2.
n
Slot 10 embedded CIM #2 interfaces to Bay 3.
n
Slot 11 embedded CIM #1 interfaces to Bay 4.
n
Slot 11 embedded CIM #2 interfaces to Bay 5.
n
If the S1 switch on the Control Triple CIM card is set to take three
circuits (emulates the control triple carrier card), the following positions
are hard coded in the software:•
Slot 10 embedded CIM #1 interfaces to Bay 2.
n
Slot 10 embedded CIM #2 interfaces to Bay 3 .
n
Slot 10 embedded CIM #3 interfaces to Bay 6.
n
Slot 11 embedded CIM #1 interfaces to Bay 4.
n
Installation