7. Select the Customer Data Entry application by entering "2". The
display returns:
ENTER USERNAME :
8. Enter the INSTALLER level of access. The display returns:
ENTER PASSWORD:
9. Enter the required password to access Customer Data Entry. The
default password is 1000.
A list of the system's forms is displayed.
10. Select Form 04 and press the return key once to enable the software
options that were purchased .You must enter the Maximum Devices
and Maximum ACD Agents options, if these options are purchased.
For a seven cabinet configuration set option 71 to 3 bays.
Confirm. Set option 72 to 3 bays. Confirm. Enter to save the
options. A message appears that states a reset is required.
Select Confirm to reset the system.
11. Enter the 8 right-most digits of the MITEL Options password to
activate the enabled features. The password must be the password
that is printed on the MOSS sheet. The MOSS sheet is included with
the system software package.
12. Press ENTER.
Enable only the purchased options listed on the MOSS sheet for
this system.
An E.8 error results when a purchased option is not enabled,
when an enabled option is not purchased, or when the MOSS
password does not match, or when the system id does not
match.
Both the top and lower seven-segment LEDs show "-" when
completed successfully.