Option Name
Slip rate - network sync limit (0-9000)/24 hrs
BER - maintenance limit
(10**-n, n = (3,4,5,6))/hr
BER - service limit
(10**-n, n = (3,4,5,6))/hr
Framing losses - maintenance limit
(0-9000)/24 hrs
Framing losses - service limit
(0-9000)/24 hrs
RTS timer - service limit exceeded (1-255 min) 30
RTS timer - net slip limit exceeded (1-255 min) 30
RTS timer - after alarm (0-300 sec)
10. Form 43, T1 Link Assignment
Assign the ISDN trunk T1 Link Descriptor to slot 6 and/or slot 8
n
on the PRI card bay.
11. Form 44, T1 Network Sync
Enter the links, according to their PLIDs, in the order that you
n
want them to be used as the network synchronization source.
12. Form 22, Modified Digit Table
DID Calling Party Number to the network interacts with the
n
current SX-200 system networking functionality and ignores
programmed node-id's in the PRI card. The Node ID Information
Element
( "*8") for Analog Networking, if programmed in the Modified
Digit Table, will be ignored by the PRI card. If *6 is programmed
in the digit modification table the DID calling extension number
is sent to the PRI card and can be sent to the network as the
calling party. The extension must belong to a block of DID
numbers purchased from the Network provider.
Programming
Value
7
3
3
225
9000
10
(Sheet 2 of 2)
115