5. Form 03, Class of Service Define: program the following table:
Device
Attendant
101 Attendant Outgoing Restriction / Room Status Set Up ENABLE
Consoles
105 Attendant Guest Room Key
Room
202 Alarm Call
Telephones
220 Do Not Disturb
232 Message Waiting SETUP Lamp
703 Message Register Applies
239 Priority Dial 0 (optional - see step 6)
244 Room Status Applies
608 SUPERSET Status Display
6. Form 19, Call Rerouting: program "Station Dial 0" routing
The "Station Dial 0" answer point for all tenants must be a
n
Console LDN or Subattendant LDN. To allow the customer's
PMS to set message waiting, you must program Day, Night 1,
and Night 2 answer points to the same LDN.
[ Tenant _____ ] Type Of Call
Station Dial 0 Routing
If you require different "Dial 0" answer points for Day, N1, and
n
N2 use "Priority Dial 0" as an alternate method.
7. Form 34, Directed I/O: program the PMS.
EXT NUM
From Form 12
8. Connect the Dataset to the programmed PLID.
All three Dataset LED's should light. If not, verify your
n
programming and hardware connections.
COS Option
Same LDN
PRINTOUT
PMS
AUTOPRINT
Day
N1
Same LDN
PRINTOUT TYPE
NO
Programming
Status
ENABLE
ENABLE
ENABLE
ENABLE
ENABLE
ENABLE
DISABLE
DISABLE
N2
Same LDN
GUARANTEED