Mitel SX-200 EL Technician's Handbook page 128

Hide thumbs Also See for SX-200 EL:
Table of Contents

Advertisement

Technician's Handbook
within that range, those trunks are skipped. The trunk number sequence
is incremented each time a trunk is skipped. If the trunk number is
incremented to a value that is already used, the sequence continues to
increment until a free number is found. The trunk numbers restart at 1
if necessary. An error message is displayed if there are no more free
trunk numbers.
NOTE:
BRI trunks are not supported.
To program a range of trunks:
1. Program the first trunk in the range. Enter values for the COS, TEN,
DAY, N1, N2, CDN fields.
2. Press RANGE PRGRM.
The system displays: FROM BAY: SLOT: CIRCUIT:.
3. Enter valid Bay, Slot and Circuit numbers for the first trunk and press
the ENTER softkey.
The system displays: TO BAY: SLOT: CIRCUIT:.
4. Enter valid Bay, Slot and Circuit numbers for the last trunk and press
the ENTER softkey.
The system copies the values from the first trunk to all the trunks
specified in the range.
118