Programming a Dial-In Trunk

1. Form 01, System Configuration
Program a trunk card that meets the trunk type requirements.
n
2. Form 13, Trunk Circuit Descriptor
Create a trunk circuit descriptor that corresponds to the type of
n
trunk that you are programming.
3. Form 03, Class of Service
Assign trunk options only.
n
4. Form 15, Dial-in Trunks
Assign COS, COR, and Tenant.
n
Assign a separate COS for the Dial-In Trunk.
Column N lists the number of expected digits.
n
If this digit is 0, the system treats this as a Tie trunk. If this digit
is not 0, the system treats this as a DID trunk.
Column M lists the number of digits to absorb. To absorb no
n
incoming digits, set to 0. To absorb n digits, enter n (a whole
number).
Column X defines the number of digits to insert.
n
Do not insert 0 as a blank. To insert no digits, leave blank.To
insert digits, enter the actual digits.
Assign a Trunk Name if desired. This name appears on the
n
consoles and on the set displays for incoming and outgoing
calls.
Programming