Table 30 shows the Main Control Card numeric display error codes
which may appear during start-up. Also shown are the most likely
causes of the error condition.
Table 30: Main Control Card Power-Up Error Code Summary
Error Code
(blank)
0
E
0
E
E
E
1
3
4
or
E
2
E
E
E
6
7
8
or
E
b.
E
C
Sequence:
2 3 8
9
b
Faulty power system - refer to that procedure.
Faulty Main Control Card.
Faulty or loose flea clip W3 (if applicable)
Faulty Main Control Card.
Unseated DRAM Module or DX Module.
Faulty DRAM or DX module (see Note).
Faulty Main Control Card.
E
5
Unseated EPROM IC.
Faulty EPROM IC - replace Main Control Card.
Unseated DRAM Module.
E
9
Faulty DRAM Module - replace Main Control
Card.
Please note difference between "E" and "E.".
(See below in this table for E. codes.)
Faulty disk drive connections.
Faulty installation of diskette.
Incorrect or damaged diskette - ensure that the
write protect sticker has been removed.
Faulty diskette - replace.
Incorrect setting of switch S3 on Main Control
Card - ensure that it is in the OFF, or OPEN po-
sition (pointed upward with respect to the board).
Faulty disk drive.
Faulty Main Control Card.
System will not boot, unable to change system
configuration.
Faulty power system - refer to that procedure.
E
b
No disk in drive, bad drive, bad disks.
Likely Cause(s)
Installation
(Sheet 1 of 2)
183