Warning: High voltage is present in the system when the
system is Off and the power cord is unplugged. This is due to
the Uninterruptible Power Supply (UPS). Make sure you
follow the correct shutdown procedure. See
the System" on page
Right Side Door - Upper
Allows access to the right side Z stage components. To remove the panel, loosen
the four panel retaining screws (the screws do not have to be removed).
Right Side Door - Lower
Allows access to some of the electronic bay components such as the computer
case, CD-ROM, in-line vacuum filter, keyboard, monitor connectors, and the
vacuum system. To remove the panel, loosen the four panel retaining screws (the
screws do not have to be removed).
Left Side Door - Upper
Allows access to the left side Z stage components. To remove the panel, loosen
the four panel retaining screws (the screws do not have to be removed).
Left Side Door - Lower
Allows access to the air compressor, material drying system, flow meter, and
some electronics bay components. To remove the panel, loosen the four panel
retaining screws (the screws do not have to be removed).
4-4.
3-4
"Powering Down