Chapter 3: System Components; System Protection; Main Circuit Breaker; Thermal Cut-Out Fuses - Stratasys Fortus 360mc User Manual

Hide thumbs Also See for Fortus 360mc:
Table of Contents

Advertisement

Chapter 3: System
Components
This chapter describes the system components of the Fortus
360mc/400mc system. Information on model materials and tips
that can be used by the system are also included in this chapter.

System Protection

Main Circuit Breaker

If the system encounters a high current surge, the main circuit breaker trips,
protecting the system's electrical and electronic components. The circuit breaker
is located at the right, rear corner of the system (as viewed from the rear). To
return the system to operation, reset the circuit breaker. This is accomplished by
pushing the circuit breaker handle all the way down and then back up.

Thermal Cut-Out Fuses

There are two thermal cut-outs installed on the system. When a cut-out reaches its
set temperature, it opens, and power to the system is removed. This prevents
damage to the system if an overheat condition occurs. Contact Customer Support
if a thermal cut-out opens.

UPS

Warning: Due to the UPS, High voltage is present in the
system when the power cord is uplugged.
The UPS (Uninterruptible Power Supply) unit is a battery standby system that
supplies AC voltage to the processor and cooling fans in the event of an AC
voltage power loss. It does not run the entire system.
In the event of an overcurrent condition, the UPS is protected by a combination
power switch and circuit breaker that is located directly above the main breaker.
(Figure
3-1)
3-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortus 400mc

Table of Contents