Manual Calibration

Manual Z Stage Zero

Note: If the Auto Z Stage Zero calibration fails, Manual Z
Stage Zero Calibration must be performed. This procedure
manually sets the model liquefier tip to the Z Zero location.
1.
Install a new build sheet and verify that vacuum is present.
2.
Run Manual Z Stage Zero Calibration
A.
B.
C.
D.
E.
F.
G.
From the Main Menu select Operator Control and press Enter.
Build Job..
>Operator Control..
Modeler Status..
Maintenance..
Select Calibrate and press Enter.
Unlock Door <E>
Load/Unload Mtl..
Change Tips/Mtl..
>Calibrate..
Select Set Z Stage Zero and press Enter.
>Set Z Stage Zero..
AutoCal Tips <E>
Tip Offset Value..
AutoHome XYZ <E>
Select Set Manual Z Zero and press Enter.
>Set Manual Z Zero <E>
Modify Current Z Zero..
Auto Z Zero Calibrate <E>
The head will begin to move and the display will show:
*Positioning.
After the head completes its move the display will show:
>Unlock Door <E>
Set Distance = 0.100 in <E>
Set Z Stage =
0 <E>
*Move Z STage
+Z<9>
Using the operator control panel, raise the platen until the build sheet is
almost touching the model liquefier tip.
|*Tips: Model T16
|*
Support T16
| Temp Control..
| Move Head/Stage..
| Calibration Job <E>
Please Wait ...
(Z:
0.010)
-Z<3>
6-6