Screen Symbols

The following symbols are used in the menu displays.
Symbol
<E>
<E>..
".."
":"
" = "
" * "
(!)
" ! ! "
C

Powering Up the System

1.
Turn the system ON by pressing the flashing green button
• The Power up message is displayed.
2.
If there is a completed part in the system, select Unlock Door <E>, and
remove the part from the system. Install a new build sheet and close the door.
3.
Verify that the air pressure gauge (located in the canister bay) reads 36-40 psi.
(External air should be 48-52 psi.)
4.
Select
• The system will find the home position for the X, Y, and Z axes. This must
5.
If the system has been powered down long enough for the oven to cool, allow
the oven to oven to heat and stabilize for at least four hours before performing
system calibrations or part build.
Description
Push ENTER to execute the command line. (The cur-
sor ">" must be on the same line.)
Push ENTER to execute command line. Also pushes
you into another menu.
Tells you that this line is a menu change. It implies
that you may return without executing a com-
mand.
Indicates that this command line value changes.
Value displayed in the command line is user
changeable.
Indicates that this is a comment line. (Symbol is
shown at beginning of line.)
Displayed at the end of a line in the job queue or
sample queue. Indicates insufficient material avail-
able; wrong type of material loaded; or wrong tip
installed. Select line and press <.> (Dot key) to show
details.
Displayed at start of Warning message.
Temperatures are displayed in Celsius only.
and press ENTER.
AutoHome XYZ
be done before any parts can be built.
4-3
(Figure
4-1).