5.2.3 Motor data/characteristic curve parameter

Parameter
Setting value/description/note
{factory setting}
Pos : 335 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P200- P299/Param eter P200 – Motorliste - Allgemei ner Teil [BU 0180, BU 0200, BU0500, SK 2xx E-FDS] @ 41\m od_1586429779497_14638.docx @ 2600922 @ @ 1
Motor list
P200
(motor list)
0 ... 73
The motor data factory setting can be changed with this parameter. The factory setting in
parameters P201 ... P209 is a 4-pole IE1 DS standard motor with the rated VFD output setting.
{ 0 }
By selecting one of the possible digits and pressing the ENTER key, all of the motor parameters
(P201 ... P209) are set to the selected standard power. The motor data is based on a 4-pole three-
phase standard motor. The motor data for NORD IE4 motors can be found in the final section of the
list.
Note:
As P200 is = 0 again after input acknowledgment, the set motor can be controlled via the parameter
P205.
If IE2/IE3 motors are used, after selecting an IE1 motor (P200), the motor data in P201 ... P209
must be adapted to the data on the motor nameplate.
Pos : 336 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P200- P299/Param eter P200 – Motorliste - D IP - Sc halter [SK 2xx E] @ 2\m od_1346931673014_14638.docx @ 42256 @ @ 1
NOTE:
Pos : 337 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P200- P299/Param eter P200 – Motorliste [SK 2xxE, SK 5xx E] @ 6\m od_1421165368263_14638.docx @ 199043 @ @ 1
148
Information
If DIP switch S1:7 (50/60 Hz operation (chapter 4.3.2.2)) is switched, the
corresponding rated motor data according to the rated VFD power output from list
P200 is reloaded.