NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 540 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Param eter P543 – Bus-Is twert 1- 3 [SK 1x0E, SK 2xxE, SK 2xx E-FDS] @ 2\mod_1346932171510_14638.doc x @ 43316 @ @ 1
P543
[-01]
Bus actual value 1 ... 3
...
(actual bus value 1 ... 3)
[-03]
0 ... 57
The return status value can be selected for bus actuation in this parameter.
{ [-01] = 1 }
NOTE:
{ [-02] = 4 }
{ [-03] = 9 }
[-01] = bus actual value 1
(Definition of frequencies (chapter 8.10))
Pos : 541 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Param eter P543 – Bus-Is twert 1- 3_Einstellung en [SK 2xx E] @ 9\m od_1448353878755_14638.docx @ 266102 @ @ 1
10 = ... 11 reserved, Posicon
12 = BusIO Out Bits 0-7
13 = ... 16 reserved, Posicon
17 = Value analog input 1,
18 = Value analog input 2,
* assignment of the digital inputs for P543 = 5
Bit 0 = DigIn 1 (VFD)
Bit 4 = PTC thermistor input (VFD)
Bit 8 = DigIn 5 (DI1, 1st SK...IOE)
Bit 12 = DigOut 1 (VFD)
Pos : 542 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0.doc x @ 2265496 @ @ 1
202
For further details, please refer to the relevant bus manual or the description for
(P418). (Values from 0% ... 100% correspond to 0000hex ... 4000hex)
For standardization of the actual values: (please see chapter 8.9 "Standardization of
setpoint/target values").
0 = Off
1 = Actual frequency
2 = Actual speed
3 = Current
4 = Torque current (100% = P112)
5 = State digital-IO
6 = ... 7 reserved, Posicon
8 = Setpoint frequency
9 = Error code
SK2x0E: Analog input 1 (P400[-01]),
SK2x5E: AIN1 of the first I/O
extension SK xU4-IOE (P400 [-03]))
SK2x0E: Analog input 2 (P400[-02]),
SK2x5E: AIN2 of the first I/O
extension SK xU4-IOE (P400 [-04]))
Bit 1 = DigIn 2 (VFD)
Bit 5 = reserved
Bit 9 = DigIn 6 (DI2, 1st SK...IOE)
Bit 13 = mech. brake (VFD)
[-02] = bus actual value 2
19 = Frequency Master Value (P503)
20 = Set frequency After Ramp,
"Setpoint frequency after master value ramp"
21 = Actual freq. without slip
"Actual frequency without master value slip"
22 = Speed encoder,
"Speed from encoder"
BU0210
23 = Actual frequency with slip
"Actual frequency with slip"
BU0210
24 = Lead actual freq. w. slip
"Master value, actual freq. with slip"
BU0210
53 = Actual value 1 PLC
54 = Actual value 2 PLC
55 = Actual value 3 PLC
56 = Actual value 4 PLC
57 = Actual value 5 PLC
Bit 2 = DigIn 3 (VFD)
Bit 6 = DigOut 3 (DO1, 1st SK...IOE)
Bit 10 = DigIn 7 (DI3, 1st SK...IOE)
Bit 14 = DigOut 2 (VFD) (SK 2x0E)
S
P
[-03] = bus actual value 3
(from software version V1.3)
(SW 1.3 and above)
Bit 3 = DigIn 4 (VFD)
Bit 7 = DigOut 4 (DO2, 1st SK...IOE)
Bit 11 = DigIn 8 (DI4, 1st SK...IOE)
Bit 15 = reserved
BU 0200 en-US-4920