NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 269.21 /Anl eitungen/Elektronik/FU und Starter/4. Inbetriebnahm e/AS-Interface [all e Ger äte]/Anschl uss _06_01 ( Vari anten 24V Vers orgung Peripheri e) [SK 2xx E] @ 21\m od_1528458786862_14638.docx @ 2425080 @ 5 @ 1
Variants of a 24 V supply for the peripherals (e.g. actuators)
(valid for SK 225E/ SK 235E, except –AUX, -AXB)
Pos : 269.22 /Anl eitungen/Elektronik/FU und Starter/4. Inbetriebnahm e/AS-Interface [all e Ger äte]/INFORM ATION - Verw endung W andmontageki t mit Lüfter [SK 200E] @ 22\m od_1530175201185_14638.docx @ 2429040 @ @ 1
Information
The following must be noted if the device is operated with a wall mounting kit type SK TIE4-WMK-L-...
( Section 2.1.3.2 "Wall mounting kit with fan"):
Supply of the fan via the frequency inverter is not permissible
Power the fan via a separate 24 V DC power supply: „Variant 2 – Use of an optional mains unit SK xU4-
"
24V-...
).
Pos : 269.23 /Anl eitungen/Elektronik/FU und Starter/4. Inbetriebnahm e/AS-Interface [all e Ger äte]/Anschl uss _06_02 ( Vari anten 24V Vers orgung Peripheri e) [SK 2xx E] @ 22\m od_1530176240171_14638.docx @ 2429076 @ @ 1
Variant 1 – connection to 24 V (terminal 44)
The limit of 60 mA for the maximum load (total current) must be complied with.
Connection example:
124
Use of a wall mounting kit with fan
BU 0200 en-US-4920