NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 670 /Anleitungen/El ektr onik /FU und Starter/6. M eldung en zum Betriebsz ustand/Störm eldung en (Auflistung)/F ehl er E010 [SK 180E/SK 2x xE/SK2x xE-FD S] @ 40\mod_1575965968975_14638.docx @ 2581241 @ @ 1
E010
10.0
Bus timeout
10.2
Bus timeout option
10.4
Init error option
10.1
System error option
10.3
10.5
10.6
10.7
10.9
Module missing/P120
Pos : 671 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0.doc x @ 2265496 @ @ 1
Pos : 672 /Anleitungen/El ektr onik /FU und Starter/6. M eldung en zum Betriebsz ustand/Störm eldung en (Auflistung)/F ehl er E011 [SK 180E ... SK 5xxE/SK 500P/SK 300P] @ 43\mod_1592386576774_14638.docx @ 2634691 @ @ 1
E011
11.0
Control terminals
Pos : 673 /Anleitungen/El ektr onik /FU und Starter/6. M eldung en zum Betriebsz ustand/Störm eldung en (Auflistung)/F ehl er E012 [SK 180E/SK 2x xE/SK2x xE-FD S/SK 500P] @ 2\m od_1347454267926_14638.docx @ 46727 @ @ 1
E012
12.0
External watchdog
12.1
Limit moto./Customer
"Motor switch-off limit"
12.2
Limit gen.
"Generator switch-off limit"
12.3
Torque limit
228
(Telegram timeout/bus off 24 V int. CANbus
Data transfer is faulty. Check P513.
Check physical bus connections
Check bus protocol program process.
Check bus master.
Check 24 V supply of internal CAN/CANopen bus.
Node guarding error (internal CANopen)
Bus off error (internal CANbus)
Telegram timeout
Telegram transfer is faulty.
Check physical bus connections
Check bus protocol program process.
Check bus master.
PLC is in the "STOP" or "ERROR" state.
Initialization error in bus module
Check bus module current supply.
DIP switch setting of a connected I/O extension
module is incorrect
System error bus module
Further details can be found in the respective
additional bus instructions.
I/O extension:
Incorrect measurement of the input voltage or undefined
provision of the output voltage due to error in
reference voltage generation.
Short circuit at analog output
The module entered in parameter (P120) is not available.
Check connections
A/D inverter error
Internal customer unit (internal data bus) faulty or damaged
by radio radiation (EMC)
Check control connections for short circuit.
Minimize EMC interference by laying control and power
cables separately.
Device and shielding must be well grounded.
The Watchdog function is selected at a digital input and the
impulse at the corresponding digital input is not present for
longer than the time set in parameter P460 >Watchdog
time<.
Check connections
Check setting P460
The drive switch-off limit (P534 [-01]) has triggered.
Reduce load on motor
Set higher value in (P534 [-01]).
The generator switch-off limit (P534 [-02]) has triggered.
Reduce load on motor
Set higher value in (P534 [-02]).
Limit from potentiometer or setpoint source has switched off.
P400 = 12
BU 0200 en-US-4920