E010
10.0
Bus timeout
10.2
Bus timeout option
10.4
Init error option
10.1
System error option
10.3
10.5
10.6
10.7
10.9
Module missing/P120
Pos : 671 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0.doc x @ 2265496 @ @ 1
Pos : 672 /Anleitungen/El ektr onik /FU und Starter/6. M eldung en zum Betriebsz ustand/Störm eldung en (Auflistung)/F ehl er E011 [SK 180E ... SK 5xxE/SK 500P/SK 300P] @ 43\mod_1592386576774_14638.docx @ 2634691 @ @ 1
E011
11.0
Control terminals
Pos : 673 /Anleitungen/El ektr onik /FU und Starter/6. M eldung en zum Betriebsz ustand/Störm eldung en (Auflistung)/F ehl er E012 [SK 180E/SK 2x xE/SK2x xE-FD S/SK 500P] @ 2\m od_1347454267926_14638.docx @ 46727 @ @ 1
E012
12.0
External watchdog
12.1
Limit moto./Customer
"Motor switch-off limit"
12.2
Limit gen.
"Generator switch-off limit"
12.3
Torque limit
228
(Telegram timeout/bus off 24 V int. CANbus
•
Data transfer is faulty. Check P513.
•
Check physical bus connections
•
Check bus protocol program process.
•
Check bus master.
•
Check 24 V supply of internal CAN/CANopen bus.
•
Node guarding error (internal CANopen)
•
Bus off error (internal CANbus)
Telegram timeout
•
Telegram transfer is faulty.
•
Check physical bus connections
•
Check bus protocol program process.
•
Check bus master.
•
PLC is in the "STOP" or "ERROR" state.
Initialization error in bus module
•
Check bus module current supply.
•
DIP switch setting of a connected I/O extension
module is incorrect
System error bus module
•
Further details can be found in the respective
additional bus instructions.
I/O extension:
Incorrect measurement of the input voltage or undefined
provision of the output voltage due to error in
reference voltage generation.
•
Short circuit at analog output
The module entered in parameter (P120) is not available.
•
Check connections
A/D inverter error
Internal customer unit (internal data bus) faulty or damaged
by radio radiation (EMC)
•
Check control connections for short circuit.
•
Minimize EMC interference by laying control and power
cables separately.
•
Device and shielding must be well grounded.
The Watchdog function is selected at a digital input and the
impulse at the corresponding digital input is not present for
longer than the time set in parameter P460 >Watchdog
time<.
•
Check connections
•
Check setting P460
The drive switch-off limit (P534 [-01]) has triggered.
•
Reduce load on motor
•
Set higher value in (P534 [-01]).
The generator switch-off limit (P534 [-02]) has triggered.
•
Reduce load on motor
•
Set higher value in (P534 [-02]).
Limit from potentiometer or setpoint source has switched off.
P400 = 12